1 Channel 12v 30A Opto Isolated Relay Module

Model : MOD-00065

Supplier : Techshop Bangladesh

TechshopBD, Bangladesh

Pricing
Quantity
Price

1 - 9
BDT309.96

10 - 99
BDT299.14Save BDT 10.82

100 +
BDT294.80Save BDT 15.16

Green 20 Available

You may also be interested in

 
Summary:
1 Channel 12v 30A Opto Isolated Relay Module

The standard 1 Channel 12v 30A Opto Isolated Relay Module, using of High-level voltage signals to trigger, only needs 3mA current signal to drive the 30A load relay. Use of high-quality power relay, high-withstand voltage transistor, red & green signal lights assures accurate and stable performance. Can be used in various types of power control occasions.

1. Using of high-quality relay, normally open relay contacts maximum load: AC 0--250V/30A, DC 0--  30V/30A;
2. Using of high-withstand voltage transistor, strong driving ability, stable performance, trigger current of 3mA;
3. Working voltage:12V

4. The relay using of high-level voltage signals to trigger, high-level voltage signals can be DC power supply positive, also can be microcontroller I/O port set high;
5. The power indicator (red LED), relay status indicator (Green LED);

The relay module outputs(3-wire interface with terminal blocks, very convenient)
1.NO: the relay normally open contacts;
2.COM: the Relay common contact;
3.NC: the relay normally closed contacts.

Login to post comments.
anon
Seepolash | Apr 26,2015 at 01:32 AM
Q1:Does the module need 2 separate dc power supply,one for the board and another for the relay,or it can be run by 1 single dc supply?

Q2: Can I run a 2hp water pump (9 to 12 A)for 30 to 60 minutes using this module?
anon
A.R | Apr 27,2015 at 10:31 AM
1) It's better to use two seperate power supplies but one will work too.
2)yes.
anon
Shariful.sumon | Jan 31,2016 at 04:20 PM
For water pumps the starting current is usually 5-6 times of the fully running current which occurs for maximum 1 second. Are you sure that, your relay can withstand that? Have you tested it?
anon
A.R | Jan 31,2016 at 05:45 PM
No. In that case if it crosses 30A even for a moment, it will not withstand the current. The user gotta make sure that the current never crosses the relay's maximum current rating.
anon
Shariful.sumon | Jan 31,2016 at 08:35 PM
by the way, what is the power rating of the relay?
anon
A.R | Feb 1,2016 at 10:02 AM
We have already provided all the info that we know about this relay. These info are available at the relays body. Power ratings are usually not mentioned in case of relays. Only nominal current is mentioned.
anon
Akteruzzaman | May 2,2015 at 09:01 PM
Question 1: Can we use 5V as Signal Or it's need 12V for Signal?

Question 2: What is the minimum Voltage for Signaling?
anon
A.R | May 4,2015 at 10:07 AM
12V
anon
Shamimz | Jun 3,2015 at 11:51 PM
how can I trigger this by Arduino?
anon
Musfikur | Aug 29,2015 at 02:15 PM
Only the Relay which is used in this module is available in techshop?
anon
A.R | Sep 1,2015 at 11:45 AM
No
anon
Shamimz | Sep 1,2015 at 10:18 AM
can i use 5v for signaling
anon
A.R | Sep 1,2015 at 11:30 AM
NO
anon
Shurid | Aug 13,2016 at 10:17 PM
Can i use it a air condition (AC) swicthing .
anon
FAHIM_REAZA | Aug 14,2016 at 09:54 AM
Dear customer, this "1 Channel 12v 30A Opto Isolated Relay Module" will be work within the given voltage and current range:
>> 1HP 120VAC
>> 1/2 HP 240VAC
>> 30A 240VAC

If your maximum load is up to this range, then you can use this module.
anon
Zahidhstu | Nov 20,2016 at 06:15 PM
where i will connect ac 220 v load????
anon
A.R | Nov 21,2016 at 09:55 AM
Between NO and COM.
anon
Mtr.eee.sust | Nov 20,2016 at 08:53 PM
I need only relay not module. Can you provide me?
anon
A.R | Nov 21,2016 at 10:16 AM
https://www.techshopbd.com/product-categories/relay/804/sla-12vdc-sl-c-techshop-bangladesh
anon
Zahidhstu | Jan 21,2017 at 03:04 PM
As it is made by techshopbd can you provide me only the pcb usedin th module?
Thanks in advance
anon
A.R | Jan 22,2017 at 09:42 AM
Sorry. Not possible.
anon
Anindya11 | May 22,2018 at 09:01 PM
Can this relay be used to drive a DC 24/12 V High Current load?

What voltage should we give to the signal pin? Is it Arduino Logic HIGH 5V or transistor shifted 12 V? If it is transistor shifted 12V then why the 12V pins are given? Please clarify.
anon
A.R | May 23,2018 at 09:26 AM
Please see the specification tab. normally open relay contacts maximum load: AC 0--250V/30A, DC 0-- 30V/30A.
5V must be given to signal pin.